{"title":"Autoclaves Icanclave","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e Icanclave is a brand specializing in the design and manufacture of high-quality autoclaves for healthcare professionals, laboratories, and care facilities. It offers a wide range of models, from compact tabletop autoclaves to larger models, suitable for various sterilization needs.\u003cbr\u003e\u003c\/p\u003e","products":[{"product_id":"autoclave-8-litres-classe-b-avec-usb","title":"8 Liter Class B Autoclave with USB","description":"\u003ch2\u003e White autoclave 8 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\r \n- An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 170 x 320 mm\u003cbr\u003e\n - Tray size: 130 x 265 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 525 mm\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum sound level: \u0026lt;70 dB\u003cbr\u003e\r \n- Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMaintaining your autoclave\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eThe error message guide\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up. \u003cbr\u003e\n\u003cbr\u003e\n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689048973631,"sku":"49.001","price":1990.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67078.png?v=1725085963"},{"product_id":"autoclave-12-litres-classe-b-avec-usb-rose","title":"Autoclave 12 Liters Class B with USB Pink","description":"\u003ch2\u003e 12 liter pink autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689050415423,"sku":"49.002","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67098.png?v=1725085991"},{"product_id":"autoclave-18-litres-classe-b-avec-usb","title":"18 Liter Class B Autoclave with USB","description":"\u003ch2\u003e White autoclave 18 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 350 mm\u003cbr\u003e\n - Tray size: 192 x 285 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 600 mm\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689050906943,"sku":"49.003","price":2405.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67085.png?v=1725086003"},{"product_id":"autoclave-23-litres-classe-b-avec-usb","title":"23 Liter Class B Autoclave with USB","description":"\u003ch2\u003e White autoclave 23 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\r \n- An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 450 mm\u003cbr\u003e\n - Tray size: 192 x 380 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2200W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 690 mm\u003cbr\u003e\n - Net weight: 53 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\r \n- Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n4. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 5. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 6. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 7. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 9. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689060671807,"sku":"49.004","price":2795.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67101.png?v=1725086237"},{"product_id":"autoclave-12-litres-classe-b-avec-usb","title":"12 Liter Class B Autoclave with USB","description":"\u003ch2\u003e White autoclave 12 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689535250751,"sku":"49.005","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67117.png?v=1725094076"},{"product_id":"autoclave-18-litres-classe-b-avec-usb-vert","title":"Autoclave 18 Liters Class B with USB Green","description":"\u003ch2\u003e 18 liter green autoclave class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 247 x 350 mm\u003cbr\u003e\n - Tray size: 192 x 285 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 490 x 455 x 600 mm\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689536266559,"sku":"49.006","price":2405.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67093.png?v=1725094108"},{"product_id":"autoclave-8-litres-classe-b-avec-usb-noir","title":"Autoclave 8 Liters Class B with USB Black","description":"\u003ch2\u003e Black autoclave 8 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 170 x 320 mm\u003cbr\u003e\n - Tray size: 130 x 265 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 525 mm\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689544163647,"sku":"49.007","price":1990.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67123.png?v=1725094236"},{"product_id":"autoclave-12-litres-classe-b-avec-usb-noir","title":"Autoclave 12 Liters Class B with USB Black","description":"\u003ch2\u003e Black autoclave 12 liters class B with USB\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\r \n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - Chamber dimensions: 200 x 360 mm\u003cbr\u003e\n - Tray size: 156 x 295 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - 2000W\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - External dimensions: 420 x 370 x 595 mm\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\r \n- EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Connect the printer (sold separately).\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer (not included) will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e \u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49689544622399,"sku":"49.008","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/67095.png?v=1725094250"},{"product_id":"joint-de-porte-pour-autoclave-icanclave","title":"Door seal for Icanclave autoclave","description":"\u003cp\u003e Please note that depending on arrivals, the color of the seal may change.\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"8L","offer_id":49690128777535,"sku":"49.009.01","price":61.5,"currency_code":"EUR","in_stock":true},{"title":"12L","offer_id":49690128810303,"sku":"49.009.02","price":68.5,"currency_code":"EUR","in_stock":true},{"title":"18 L \u0026amp; 23 L","offer_id":49690128843071,"sku":"49.009.03","price":71.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/83535.png?v=1725111866"},{"product_id":"autoclave-blanc-8-litres-classe-b-avec-usb-et-imprimante-integree","title":"White Autoclave 8 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 8 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\r \n- Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003c\/p\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 420 x 370 x 525 mm\u003cbr\u003e\n - Tray dimensions: 265 x 130 mm\u003cbr\u003e\r \n- Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 37 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\r \n- Internal printer (allows printing of sterilization cycle reports on thermal paper after the end of the cycle.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 2 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\r \n1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691004502335,"sku":"49.014","price":1990.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/Autoclave-Blanc-8-Litres-Classe-B-avec-USB-et-imprimante-integree-Icanclave-Autoclaves-219977234.webp?v=1751882679"},{"product_id":"autoclave-blanc-12-litres-classe-b-avec-usb-et-imprimante-integree","title":"White autoclave 12 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 12 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n \u003cp\u003e\u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\r \n- Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 420 x 370 x 595 mm\u003cbr\u003e\n - Tray dimensions: 315 x 160 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 40 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\r \n- Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the cycle is complete.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\r \n\u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691004600639,"sku":"49.015","price":2171.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/Autoclave-blanc-12-Litres-Classe-B-avec-USB-et-imprimante-integree-Icanclave-Autoclaves-219976979.webp?v=1760090700"},{"product_id":"autoclave-blanc-18-litres-classe-b-avec-usb-et-imprimante-integree","title":"White Autoclave 18 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 18 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured. \u003cbr\u003e\n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 600 mm\u003cbr\u003e\n - Tray dimensions: 285 x 192 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 47 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the cycle is complete.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691004797247,"sku":"49.016","price":2405.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/87110.png?v=1725140475"},{"product_id":"autoclave-blanc-23-litres-classe-b-avec-usb-et-imprimante-integree","title":"White autoclave 23 Liters Class B with USB and integrated printer","description":"\u003ch2\u003e 23 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\n - Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured. \u003cbr\u003e\n- Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 690 mm\u003cbr\u003e\n - Tray dimensions: 380 x 192 mm\u003cbr\u003e\n - Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 1750W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 53 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\r \n\u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\n - Internal printer (allows printing of sterilization cycle reports on thermal paper after the cycle is complete.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\r \n- 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\n 1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\r \n5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\n 6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\r \nAfter selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\n Once the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691004862783,"sku":"49.017","price":2795.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/87113.png?v=1725140487"},{"product_id":"autoclave-blanc-29-litres-classe-b-avec-usb-et-imprimante-integree","title":"White autoclave 29 liters Class B with USB and integrated printer","description":"\u003ch2\u003e 29 litre white autoclave class B with USB and integrated printer\u003c\/h2\u003e\n\n\n\u003cp\u003e \u003cstrong\u003eDetails of guarantees in the attachments.\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eSecurity\u003c\/strong\u003e\u003cbr\u003e\n - The cycle will not start if the door is not closed properly.\u003cbr\u003e\r \n- Automated safety with double hydraulic locking device, prevents the door from opening while the chamber is under pressure.\u003cbr\u003e\n - Safety valves prevent pressure generator and camera.\u003cbr\u003e\n - A safety thermostat prevents overheating in the chamber and the generator\u003cbr\u003e\n - An automatic safety lock prevents accidental opening of the door during the sterilization process protector automatically cuts off the electric power if somewhere has a short circuit or the power supplier is not very stable.\u003cbr\u003e\n - Failure alarm indicates failure cycle and detailed error code.\u003cbr\u003e\n - Door alarm indicates that the door is not secured.\u003cbr\u003e\n - Low water alarm indicates when the water tank is empty or too full.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003cbr\u003e\n - Voltage: 220-240 VAC; 50\/60Hz; 10A\u003cbr\u003e\n - External dimensions of the device: W x H x L: 490 x 455 x 860 mm\u003cbr\u003e\n - Tray dimensions: 380 x 192 mm\u003cbr\u003e\r \n- Circuit breaker: F16A \/ 400V\u003cbr\u003e\n - Nominal power: 1500 VA\u003cbr\u003e\n - 2300W\u003cbr\u003e\n - Sterilization temperature: 121°C \/ 134°C\u003cbr\u003e\n - Distilled water tank capacity: 2.5 L\u003cbr\u003e\n - Operating temperature: 5 ° C \/ 40\u003cbr\u003e\n - Relative humidity: Max. 80%, non-condensing\u003cbr\u003e\n - Net weight: 65 kg\u003cbr\u003e\n - Maximum noise level: \u0026lt;70 dB\u003cbr\u003e\n - Atmospheric pressure of 76 kPa \/ 106 kPa\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eMaintenance and Error Messages Guide for Your Autoclave\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/79-la-maintenance-de-votre-autoclave-classe-b-avec-usb\"\u003eMAINTAINING YOUR AUTOCLAVE\u003c\/a\u003e \u003ca class=\"btn btn-default\" href=\"https:\/\/www.my-podologie.com\/contenu\/82-autoclave-le-guide-des-messages-d-erreur\"\u003eTHE ERROR MESSAGE GUIDE\u003c\/a\u003e\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eComponents\u003c\/strong\u003e\u003cbr\u003e\n - Distilled water tank\u003cbr\u003e\n - LCD screen\u003cbr\u003e\n - Control Panel\u003cbr\u003e\n - Main switch\u003cbr\u003e\n - Key to drain distilled water and used\u003cbr\u003e\n - USB port\u003cbr\u003e\r \n- Internal printer (allows printing of sterilization cycle reports on thermal paper after the cycle is complete.)\u003cbr\u003e\n - Safety valve\u003cbr\u003e\n - Ventilation grille\u003cbr\u003e\n - Locking system\u003cbr\u003e\n - Power cable\u003cbr\u003e\n - Label\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAccessories included\u003c\/strong\u003e\u003cbr\u003e\n - Sterilizer\u003cbr\u003e\n - USB\u003cbr\u003e\n - 3 instrument trays\u003cbr\u003e\n - Tray support\u003cbr\u003e\n - Handle for extracting the trays\u003cbr\u003e\n - Door adjustment tool\u003cbr\u003e\n - 2 drain pipes\u003cbr\u003e\n - Advice for the door\u003cbr\u003e\n - Instruction manual\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eRegulations\u003c\/strong\u003e\u003cbr\u003e\n - 93\/42\/EEC The Medical Care Directive.\u003cbr\u003e\n - 97\/23\/EEC pressure equipment directive.\u003cbr\u003e\n - EN 13060 Small steam sterilizers.\u003cbr\u003e\n - EN 61326, EN 61000 EMC.\u003cbr\u003e\n - EN 61010-1, UL 61010-1 safety requirements.\u003cbr\u003e\n - EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eAutoclave process step by step\u003c\/strong\u003e\u003cbr\u003e\r \n1. Open the door, take out the tools and accessories that are in the sterilization chamber, remove the packaging and clean them.\u003cbr\u003e\n\u003cbr\u003e\n 2. Connect the power cord to a suitable power source.\u003cbr\u003e\n\u003cbr\u003e\n 3. Plug in the printer.\u003cbr\u003e\n\u003cbr\u003e\n 4. Power on: The main switch is located on the front, bottom right of the unit. Once turned on, the LCD screen will light up and the basic symbols of autoclave operation, such as door position, water level, sterilization program, date, time will light up.\u003cbr\u003e\n\u003cbr\u003e\n 5. Remove the top cover and fill the tank with distilled water. If you hear a beep, you have exceeded the permitted water level in the tank. Empty the excess water until the alarm goes off.\u003cbr\u003e\n\u003cbr\u003e\r \n6. Preparation of the material to be sterilized: place the instruments on the different trays, and separate them according to their materials. If the instruments are not made of stainless steel, use sterilization bags. These must not be in contact. Check that all the instruments are placed correctly, so that water does not remain in the hollow parts. Do not overload the instrument trays and do not put them in direct contact with the walls of the sterilization chamber. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.\u003cbr\u003e\n\u003cbr\u003e\n 7. Select the sterilization program.\u003cbr\u003e\n\u003cbr\u003e\n 8. Start the sterilization cycle.\u003cbr\u003e\n After selecting the sterilization program, place the instruments on the trays in the chamber using the plastic clamp provided.\u003cbr\u003e\r \nOnce the instruments are securely placed inside, close the door. Caution: Be sure to close the door properly, otherwise the autoclave will not be able to operate.\u003cbr\u003e\n\u003cbr\u003e\n 9. Start the sterilization program.\u003cbr\u003e\n Press the start button, the autoclave will start working for about 30-75 minutes.\u003cbr\u003e\n\u003cbr\u003e\n 10. End of the sterilization cycle.\u003cbr\u003e\n Once the sterilization cycle is complete, the printer will automatically print the complete cycle report.\u003cbr\u003e\n Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will alert you with an audible signal once the sterilization cycle is complete.\u003cbr\u003e\n Precaution: Use the plastic tweezers to remove the instruments.\u003cbr\u003e\n\u003cbr\u003e\n \u003cstrong\u003eIMPORTANT: Do not reuse used water after emptying the tank.\u003c\/strong\u003e\u003c\/p\u003e\n\n","brand":"Icanclave Autoclaves","offers":[{"title":"Default Title","offer_id":49691005911359,"sku":"49.018","price":4420.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/files\/69690.png?v=1725140608"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6266\/6815\/collections\/ICANCLAVE.png?v=1758096749","url":"https:\/\/www.my-medical.es\/en\/collections\/icanclave-autoclaves.oembed","provider":"My Médical","version":"1.0","type":"link"}